Pleural cryptococcosis is uncommon after solid-organ transplantation and may lack respiratory symptoms [1,2]. Guidelines address systemic antifungal therapy but do not establish an intrapleural amphotericin B regimen [2,3]. We describe a reproducible closed-circuit procedure used as an adjunct to systemic treatment.
A 65-year-old man underwent bilateral lung transplantation in December 2022 for interstitial lung disease. Maintenance immunosuppression comprised tacrolimus, mycophenolate mofetil and prednisone, with weekly inhaled amphotericin B prophylaxis. He was admitted with declining pulmonary function, asthenia, nausea, reduced oral intake and acute kidney injury (creatinine 3.25mg/dL), without fever or respiratory symptoms. Computed tomography showed right-predominant bilateral pleural and enlarging pericardial effusions. Right thoracentesis yielded serous, non-inflammatory fluid (pH 7.41, glucose 140mg/dL, protein 1.9g/dL and LDH 59U/L); culture grew Cryptococcus neoformans. Transbronchial biopsy showed no acute cellular rejection and brain magnetic resonance imaging was normal. Recovery of C. neoformans from pericardial fluid and detection of cryptococcal antigen in cerebrospinal fluid supported disseminated infection. An 18-Fr right pleural drain was inserted. Before each session, the nurse verified the prescription, patient, drain and circuit, and recorded baseline pain, vital signs and oxygen saturation. The pleural cavity was irrigated with two 500-mL volumes of 0.9% saline. Liposomal amphotericin B 50mg in 100mL of 5% glucose was instilled once daily for five days; the drain was clamped for 2h with clinical monitoring, then unclamped and suction gradually restored to −20cmH2O (Fig. 1). All sessions were completed without pain, respiratory deterioration or local adverse events. Pleural culture was negative after five days and the drain was removed on day 7. Follow-up ultrasonography showed only a minimal residual pocket and repeat thoracentesis was unnecessary. Concomitant systemic therapy comprised intravenous liposomal amphotericin B 140mg/24h for 10 days, fluconazole 400mg/8h for 10 days and flucytosine 1500mg/6h. Drug-related toxicities and persistent renal failure prompted a change to oral isavuconazole, continued for 18 months after discharge. Renal function and cognition had recovered at discharge, while weekly inhaled amphotericin B prophylaxis was maintained.
Closed circuit and standardised workflow for intrapleural liposomal amphotericin B. (A) Closed circuit: 1, 0.9% sodium chloride; 2, infusion set; 3, three-way stopcock; 4, Y-connector; 5, pleural-drain connection; and 6, collection bag. (B) Sequence: baseline assessment; two 500-mL 0.9% sodium chloride irrigation cycles; intrapleural instillation of liposomal amphotericin B 50mg in 100mL of 5% glucose once daily for 5 days; 2-h clamping with clinical monitoring; gradual restoration of suction to −20cmH2O; and assessment of drain-removal criteria. OpenAI ChatGPT was used to assist with the design and layout of the explanatory workflow in panel B. The original circuit photograph in panel A was not generated or altered by AI. All elements were reviewed by the authors.
Published experience with intrapleural amphotericin B is limited and concerns mainly non-cryptococcal fungal empyema, with heterogeneous formulations and regimens [4,5]. This case provides a detailed administration and monitoring workflow for intrapleural liposomal amphotericin B. The procedure was feasible and well tolerated when delivered by a trained team, but microbiological clearance cannot be attributed exclusively to the local intervention because systemic antifungal therapy was administered simultaneously. Intrapleural treatment should therefore be considered an individualised adjunct rather than a replacement for systemic therapy; further reports are required to define its pharmacokinetics, dosing, safety and effectiveness.
Declaration of generative AI and AI-assisted technologiesOpenAI ChatGPT was used to assist with the design and layout of the explanatory workflow in Fig. 1. The original circuit photograph was not generated or altered by AI. All elements were reviewed by the authors, who take full responsibility for the figure's accuracy and content.
Informed consentWritten informed consent was obtained from the patient for publication of the de-identified clinical information and the circuit photograph.
FundingThis work received no specific funding.
Conflicts of interestThe authors declare no conflicts of interest.